Philips Microstream2 MicroPod EtCO2 CO2 module 989803183161 with interface cable

Philips Microstream2 MicroPod EtCO2 CO2 Module 989803183161 HeartStart XL+

£999.00
Skip to product information
Philips Microstream2 MicroPod EtCO2 CO2 module 989803183161 with interface cable

Philips Microstream2 MicroPod EtCO2 CO2 Module 989803183161 HeartStart XL+

£999.00

Philips Microstream2 MicroPod EtCO₂ / CO₂ Module – REF 989803183161

Price: £999 + shipping
Quantity available: 1
Condition: Used

Original Philips / Oridion Microstream MicroPod external EtCO₂ capnography module for compatible Philips patient monitoring and defibrillator systems. The unit is clearly marked REF 989803183161 and MicroPod on the manufacturer's label.

Testing

The module has been tested using 5% calibration CO₂ gas and produced a good response/outcome during our test. It is therefore offered as a tested, working used unit. As with all clinical monitoring accessories, the purchaser should carry out their own functional and calibration checks before clinical use.

Compatibility

Philips documentation lists REF 989803183161 as the Oridion MicroStream MicroPod for the Microstream EtCO₂ option used with the Philips HeartStart XL+ 861290 defibrillator/monitor. It may also be used with other compatible Philips systems that support this exact MicroPod interface; please confirm compatibility by part number and connector before purchase.

Details

  • Manufacturer: Philips Medical Systems / Oridion Medical
  • Product: MicroPod
  • Technology: Microstream / Microstream2 EtCO₂
  • REF / Part Number: 989803183161
  • Function: External sidestream / Microstream capnography interface for EtCO₂ monitoring
  • Input rating: 5 V DC, 0.6 A
  • Ingress rating: IPX2
  • Manufacture date shown on label: 2013-08
  • Included: MicroPod module with attached Philips interface cable as pictured

Note: Disposable Microstream FilterLine / CapnoLine sampling accessories are not included unless specifically shown in the photographs.

Condition

Used condition with light cosmetic signs of previous use. Housing, cable and connector are shown in the actual-item photographs. Tested with 5% calibration CO₂ gas and received a good test response.

DISCLAIMER: All medical items are sold in good clean and functioning condition unless otherwise stated. It is the buyer's responsibility to have the item professionally tested, calibrated or serviced before clinical use on humans or animals.

NOTE: Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by purchasing this equipment, indicates their acknowledgment of and agreement to the terms of this disclaimer.

CE MARKED: CE marking is visible on the product label. The purchaser is responsible for confirming suitability and regulatory requirements for the intended market and use.

FDA NOTE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If applicable, do not purchase this item unless you are an authorized purchaser. If the item is subject to FDA regulation, purchaser status may be verified before shipping.