{"product_id":"olympus-bx61trf-internal-optical-light-path-assembly-oem-microscope-part","title":"Olympus BX61TRF Motorized Focus Z-Axis Base \/ Focusing Block Assembly ND6 ND25 LBD","description":"\u003ch2\u003eOlympus BX61TRF Motorized Focus Z-Axis Base \/ Lower Frame Assembly with ND Filters\u003c\/h2\u003e\n\u003cp\u003eOlympus optical \/ light-path subassembly removed from a working BX61TRF microscope. The part contains the optical lens group, adjustment mechanism and attached motorised\/mechanical sections shown in the photograph.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Olympus\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroscope Series:\u003c\/strong\u003e BX61 \/ BX61TRF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Motorized microscope lower-frame \/ focusing assembly\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003emotorized Z-axis \/ focus mechanism\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge precision \u003cstrong\u003efocus adjustment dial\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectronic \u003cstrong\u003eFocus Up \/ Down\u003c\/strong\u003e controls\u003c\/li\u003e\n\u003cli\u003eTransmitted-light \u003cstrong\u003ebrightness increase \/ decrease\u003c\/strong\u003e controls\u003c\/li\u003e\n\u003cli\u003eBuilt-in transmitted-light filter controls:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eND6\u003c\/strong\u003e neutral-density filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eND25\u003c\/strong\u003e neutral-density filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLBD\u003c\/strong\u003e daylight colour-balancing filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOP\u003c\/strong\u003e optional filter position\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal motor, gearing and positioning mechanism\u003c\/li\u003e\n\u003cli\u003eOriginal Olympus wiring harnesses and electrical connectors\u003c\/li\u003e\n\u003cli\u003eOptical mounting \/ illumination sections retained as shown\u003c\/li\u003e\n\u003cli\u003eGenuine Olympus OEM component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eCondition\u003c\/h3\u003e\n\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe assembly was removed from an \u003cstrong\u003eOlympus BX61TRF microscope that was operational before dismantling\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThere are normal cosmetic signs of previous laboratory use, including minor marks and wear to the painted surfaces.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAll controls, wiring, connectors and mechanical sections included in the sale are shown clearly in the photographs.\u003c\/p\u003e\n\u003ch3\u003eImportant Notice\u003c\/h3\u003e\n\u003cp\u003eThis is a replacement microscope component intended for laboratory \/ technical use. The buyer is responsible for confirming compatibility with their exact Olympus microscope configuration and for installation by suitably qualified personnel.\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-size: 14pt; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: Arial; font-size: small;\"\u003e\u003cspan style=\"background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cb\u003e\u003cspan style=\"color: #ff0010;\"\u003e\u003cu\u003eDISCLAIMER\u003c\/u\u003e\u003c\/span\u003e\u003c\/b\u003e: \u003c\/span\u003eAll medical items are sold in good clean and functioning condition unless otherwise stated. It is the buyers responsibility to have the item professionally tested, calibrated or serviced before clinical use on humans or animals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: #ff0010;\"\u003e\u003cb\u003e\u003cu\u003eNOTE\u003c\/u\u003e\u003c\/b\u003e:\u003c\/span\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 13.3333px;\"\u003eRegardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by offering on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: #ff0010;\"\u003e\u003cu\u003eCE MARKED\u003c\/u\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: #ff0010;\"\u003e \u003c\/span\u003e- This product is in compliance with the essential requirements of Council Directive 93\/42\/EEC Medical Device Directive, as amended by Council Directive 2007\/47\/EC, class IIa\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"text-align: start;\"\u003e\u003cspan style=\"font-family: Arial; font-size: small;\"\u003e\u003cb\u003e\u003cu\u003e\u003cspan style=\"color: #ff0010;\"\u003eNOTE:\u003c\/span\u003e\u003c\/u\u003e\u003c\/b\u003e The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Olympus","offers":[{"title":"Default Title","offer_id":64662444835193,"sku":null,"price":599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1028\/7923\/2377\/files\/20260708_012223.jpg?v=1789941125","url":"https:\/\/www.arinna19.com\/products\/olympus-bx61trf-internal-optical-light-path-assembly-oem-microscope-part","provider":"Arinna19","version":"1.0","type":"link"}