{"product_id":"olympus-bx61trf-internal-motorized-drive-positioning-assembly","title":"Olympus BX61 BX61TRF Internal Motorized Z-Axis Focus Drive Assembly VEXTA PK544","description":"\u003ch2\u003eOlympus BX61 BX61TRF Internal Motorized Z-Axis Focus Drive Assembly VEXTA PK544\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003einternal focusing mechanism removed from an \u003cstrong\u003eOlympus BX61TRF motorized microscope\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis assembly forms part of the microscope frame’s high-precision \u003cstrong\u003emotorized Z-axis focusing system\u003c\/strong\u003e. It incorporates the stepping motor, precision mechanical drive, ball-screw mechanism, guide system, position\/sensor electronics and associated wiring shown in the photographs.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe complete BX61TRF microscope was in \u003cstrong\u003eworking condition prior to dismantling\u003c\/strong\u003e. This component was removed from that system but has not been independently powered or bench-tested after removal.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eComponent details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Olympus system component\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSource microscope:\u003c\/strong\u003e Olympus BX61 \/ BX61TRF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Motorized Z-axis \/ focusing mechanism\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor manufacturer:\u003c\/strong\u003e Oriental Motor \/ VEXTA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor model:\u003c\/strong\u003e \u003cstrong\u003ePK544-NA-C12\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor type:\u003c\/strong\u003e 5-phase stepping motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep angle:\u003c\/strong\u003e \u003cstrong\u003e0.72° \/ step\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e \u003cstrong\u003e0.75 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil resistance:\u003c\/strong\u003e \u003cstrong\u003e2.2 Ω\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePrecision threaded \/ ball-screw focusing drive\u003c\/li\u003e\n\u003cli\u003eLinear guide \/ carriage assembly\u003c\/li\u003e\n\u003cli\u003ePosition \/ limit sensing PCBs\u003c\/li\u003e\n\u003cli\u003eOriginal Olympus internal wiring harnesses and connectors\u003c\/li\u003e\n\u003cli\u003eMounting base and mechanical components included as photographed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eOlympus specifies the BX61\/BX61TRF focusing mechanism as a \u003cstrong\u003emotorized stepping-motor and ball-screw system\u003c\/strong\u003e, with cross-roller guided stage movement. The BX61 system provides high-precision Z positioning and is operated through the microscope frame and BX-UCB\/Z-drive electronics. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eCondition\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eUsed condition.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eRemoved from an \u003cstrong\u003eOlympus BX61TRF microscope that was working before dismantling\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThere are normal signs of previous use and disassembly around the mounting plate and wiring, as shown in the photographs.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe individual focus-drive assembly has \u003cstrong\u003enot been independently connected to a BX-UCB\/Z-control system after removal\u003c\/strong\u003e, so the listing should not claim a separate post-removal functional test.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Olympus BX61\/BX61TRF motorized Z-axis focusing assembly\u003c\/li\u003e\n\u003cli\u003eVEXTA PK544-NA-C12 5-phase stepping motor\u003c\/li\u003e\n\u003cli\u003eMechanical focus-drive mechanism\u003c\/li\u003e\n\u003cli\u003eSensor\/PCB assemblies\u003c\/li\u003e\n\u003cli\u003eWiring and connectors shown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eBuyer will receive exactly the same assembly shown in the photographs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center; font-size: 14pt; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: Arial; font-size: small;\"\u003e\u003cspan style=\"background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cb\u003e\u003cspan style=\"color: #ff0010;\"\u003e\u003cu\u003eDISCLAIMER\u003c\/u\u003e\u003c\/span\u003e\u003c\/b\u003e: \u003c\/span\u003eAll medical items are sold in good clean and functioning condition unless otherwise stated. It is the buyers responsibility to have the item professionally tested, calibrated or serviced before clinical use on humans or animals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: #ff0010;\"\u003e\u003cb\u003e\u003cu\u003eNOTE\u003c\/u\u003e\u003c\/b\u003e:\u003c\/span\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 13.3333px;\"\u003eRegardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by offering on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: #ff0010;\"\u003e\u003cu\u003eCE MARKED\u003c\/u\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"color: #ff0010;\"\u003e \u003c\/span\u003e- This product is in compliance with the essential requirements of Council Directive 93\/42\/EEC Medical Device Directive, as amended by Council Directive 2007\/47\/EC, class IIa\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-family: 'Times New Roman';\"\u003e\u003cspan style=\"text-align: start;\"\u003e\u003cspan style=\"font-family: Arial; font-size: small;\"\u003e\u003cb\u003e\u003cu\u003e\u003cspan style=\"color: #ff0010;\"\u003eNOTE:\u003c\/span\u003e\u003c\/u\u003e\u003c\/b\u003e The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Olympus","offers":[{"title":"Default Title","offer_id":64662444736889,"sku":null,"price":299.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1028\/7923\/2377\/files\/olympus-bx61trf-internal-motorized-drive-assembly.jpg?v=1789937478","url":"https:\/\/www.arinna19.com\/products\/olympus-bx61trf-internal-motorized-drive-positioning-assembly","provider":"Arinna19","version":"1.0","type":"link"}